Reducing Agent Delivery Module, Removing And Installing: Removing
The reducing agent tank must be removed to drain the reducing agent.
-- Remove the reducing agent tank. Refer to REDUCING AGENT TANK, REMOVING AND INSTALLING .
-- Place the reducing agent tank on a clean surface.
-- While doing so, the delivery module must face upward.
-- Clean the area around the delivery module -5-.
-- Remove the bolts -arrows-.
-- Pry out the delivery module -5- from the opening -4- with a flat-head screwdriver.
-- Remove the delivery module from the reducing agent tank.