Fuel Tank, Checking Ventilation: Notes
Special Tools And Workshop Equipment Required
- Hand Vacuum Pump VAS 6213
- Pressure Tester Kit VAS 6550
- Pressure Tester Kit - Adapter Set - Fitting VAS 6550/3-1
- Sealing Tool T10249
Test Conditions
- The ignition must be off.
Test Sequence
EVAP Canister Purge Regulator Valve 1 -N80-, Checking
-- Disconnect the hose -arrow- to the EVAP Canister Purge Regulator Valve 1 - N80- at the Evaporative Emission (EVAP) canister.
-- Connect the Hand Vacuum Pump VAS 6213 to the hose with suitable means.
-- Set the slide ring -1- on the Hand Vacuum Pump VAS 6213 in position -B- for "pressure".
-- Operate the Hand Vacuum Pump VAS 6213 several times. Pressure must increase.
If the Pressure Does Not Increase
-- Check the hose to the EVAP Canister Purge Regulator Valve 1 - N80- for leaks and damage and replace it if necessary.
If No Malfunction Can Be Found
-- Check the EVAP Canister Purge Regulator Valve 1 -N80- see Vehicle Diagnostic Tester.
If the Pressure Increases
-- Check the vent lines and EVAP canister by performing the following tests. Refer to FUEL TANK, CHECKING VENTILATION .