LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2015 >> Q3 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 21 (Turbocharger & Supercharger (Ea 888 Generation II) (2017 - 2018)) >> 21 Turbocharger, Supercharger >> Turbocharger >> Turbocharger Vacuum Diaphragm, Adjusting >> Adjusting

Turbocharger Vacuum Diaphragm, Adjusting: Adjusting

WARNING: This page is about a different car, the 2018 Audi Q3 Quattro, 2018 Audi Q3, 2017 Audi Q3 Quattro, and 2017 Audi Q3. However, it is still accessible from the selected car via links, so may be relevant.

TIP: 

It is necessary to adjust the diaphragm only if it has been removed.

-- Remove hose -arrow- from vacuum diaphragm on turbocharger.

GWWA21-10121Courtesy of AUDI OF AMERICA, LLC

-- Loosen the clamp over the linkage on the turbocharger.

-- Loosen the lock nut -2-.

GWWA21-10203Courtesy of AUDI OF AMERICA, LLC

-- Adjust the bypass flap -1- using the knurled nut -arrow- so that the flap can still just be turned by hand.

GWWA21-10122Courtesy of AUDI OF AMERICA, LLC

-- Install the lock nut hand-tight.

-- Connect the :VAS6213  and :VAS6342  to the vacuum diaphragm and to connection II on the : VAG1397A  , as illustrated.

GWWA21-10120Courtesy of AUDI OF AMERICA, LLC

-- Close the :VAS6342  on the lever -1-.

-- Set the slide ring -1- on the :VAS6213  in position -B- for "pressure".

GWWN24-10282Courtesy of AUDI OF AMERICA, LLC

-- Switch the :VAG1397B  and set the slide switch to position II.

-- Secure the :VW387  onto the turbocharger -arrow-.

GWWA21-10123Courtesy of AUDI OF AMERICA, LLC

TIP: 

The mm specifications apply to the value read out (includes 1 mm pre-load).

-- Secure the :VAS6341/1  with the :VAS6341/3  and :VAS6341/4  to the :VW387  .

-- Set the :VAS6341/1  to 1 mm tension at 0 bar.

-- Turn the :VAS6341/1  display to 0.

-- Check the dial gauge for ease of movement.

-- Operate the :VAS6213  until the :VAG1397B  displays 460 ± 5 mbar (6.67 ± 0.07 psi).

-- 4.1 mm to 4.3 mm must appear in the dial gauge; if not, turn the knurled nut until the value is displayed.

-- Tighten the lock nut hand-tight.

-- Repeat the measurement.

-- Reduce pressure to 0 mbar via :VAS6342  .

-- Set the : VAS6341/1  to 0.

TIP: 

The following measurements must be performed in one sequence. In the meantime, the pressure must not dissipate to 0.

-- Operate the :VAS6213  until the :VAG1397B  displays 460 ± 5 mbar 460 ± 5 mbar (6.67 ± 0.07 psi).

-- Read and note the value on the :VAS6341/1  .

-- Operate the :VAS6213  until the :VAG1397B  displays 650 mbar to 700 mbar (9.42 psi to 10.15 psi).

-- Reduce the pressure to 460 ± 5 mbar (6.67 ± 0.07 psi) via :VAS6342  .

-- Read and note the value on the :VAS6341/1  .

-- Add value 1 and 2 together and divide by two.

-- The result (mean value) must be 5 ± 0.25 mm.

-- If the result (mean value) is not 5 ± 0.25 mm, correct the adjustment, tighten the lock nut by hand and repeat the measurement.

-- If the result (average) is 5 ± 0.25 mm, tighten the lock nut and secure with sealing wax. Refer to parts information for the correct sealing wax.

-- Secure the locking plate -1- over vacuum diaphragm linkage.

GWWA21-10204Courtesy of AUDI OF AMERICA, LLC