Typical Enabling Conditions
WARNING: This page is about a different car, the 2014 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
ALL
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Starter | Off |
| Power switch | On (IG) |
| Time after power switch off to on (IG) | 0.5 seconds or more |
CASE 1
| Either of the following conditions is met | Conditions A or B |
| A. Both of the following conditions are met | - |
| Auxiliary battery voltage | 11 V or higher, and less than 13 V |
| Target duty cycle | Less than 70% |
| B. Both of the following conditions are met | - |
| Auxiliary battery voltage | 13 V or higher |
| Target duty cycle | Less than 80% |
CASE 2
| Current cut status | Not cut |