LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2014 >> S6 >> Repair and Diagnosis >> External Pages >> Different car >> Section 1852 (3.0L - Turbocharger & Supercharger - Engine Code(S): CGXB & CTUA) >> 21 Turbocharger, Supercharger >> Compressor >> Supercharger, Checking For Leaks

Supercharger, Checking For Leaks

WARNING: This page is about a different car, the 2015 Audi A6 Quattro, 2014 Audi A6 Quattro, 2013 Audi A6, and 2012 Audi A6. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- Secure the Turbo System Tester Kit - Adapter 13-1 VAG1687/13-1 on the bottom of the supercharger housing.

Fig 1: Attaching V.A.G 1687/13-1 To Bottom Of Supercharger
GWWA21-10457Courtesy of AUDI OF AMERICA, LLC

-- Secure the hose connections with hose clamps.

NOTE:

The supercharger is shown without the transmission holder.

-- Secure the Turbo System Tester Kit - Adapter 13-3 VAG1687/13-3 on the top of the supercharger housing.

Fig 2: Attaching V.A.G 1687/13-3 To Top Of Supercharger
GWWA21-10459Courtesy of AUDI OF AMERICA, LLC

-- Secure the hose connections with hose clamps.

-- Secure the Turbo System Tester Kit - Adapter 13-2 VAG1687/13-2 with Turbo System Tester Kit - Adapter 10 VAG1687/10 to the supercharger housing.

Fig 3: Attaching V.A.G 1687/13-2 And V.A.G 1687/10 To Supercharger
GWWA21-10460Courtesy of AUDI OF AMERICA, LLC

-- Secure the hose connections with hose clamps.

Prepare the Turbo System Tester Kit VAG1687 as follows:

Fig 4: Connecting Pressurized Air Hose To Testing Unit For Turbo Charger V.A.G 1687
GWWV21-0168Courtesy of AUDI OF AMERICA, LLC

-- Completely remove the pressure regulating valve -2- and close the valves -3- and -4-.

-- Connect the Turbo System Tester Kit VAG1687 as shown, to the compressed air using a commercially available intermediate piece -1-.

Fig 5: Connecting V.A.G 1687 To Compressed Air Using Commercially Available Intermediate Piece -1-
GWWA21-10461Courtesy of AUDI OF AMERICA, LLC

-- If there is water in the viewing glass, open the water drain plug -6- and drain the water.

Fig 6: Connecting Pressurized Air Hose To Testing Unit For Turbo Charger V.A.G 1687
GWWV21-0168Courtesy of AUDI OF AMERICA, LLC

-- Open the valve -3-.

CAUTION:

Damage could result if the pressure is set too high.

  • Pressure must not exceed 0.5 bar (7.2 psi)!

-- Set the pressure to 0.5 bar (7.2 psi) using the pressure control valve -2-.

-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.5 (7.2 psi) bar again if necessary.

-- Closes the valve -3-.

-- Inspect the charge air system for poorly sealed areas by listening, feeling, using commercially available leak detection spray or by using the Ultrasonic Tester VAG1842S.

NOTE:

For information on using the Ultrasonic Tester VAG1842S, refer to the Owner's Manual.

Release the pressure in the test circuit by pulling off the hose coupling before removing the adapter.