Hood, Adjusting
Special tools and workshop equipment required
- Gauge - Gap Adjustment 3371
Gap Dimensions for Hood
NOTE:
All dimensions are in mm with a ± 0.5 mm tolerance.
- Dimension -A- = 4.5 mm
- Dimension -B- = 4.5 mm
- Dimension -C- = 4.5 mm
- Dimension -D- = 3.0 mm
Height Adjustment Stop Buffer
- Stop Buffer
- The stop buffer -1- also works as a strike guard.
- Hood
- Adjusting BufferNOTE:
The adjusting buffers -2- are used to adjust the height of the hood.
- The adjusting buffer -2- must lightly contact the lock carrier when the hood is closed.
Hood Impact Guard, Replacing
NOTE:
The impact guard is also equipped with double-sided adhesive tape.
- Clip
- Impact Guard
- To remove, remove the clip from the hood and then remove the impact guard.
- Door
Hold Panel
- Clip
- Hold Panel
- Installation:
-- Slide the lining over the tabs on the rear edge into the holes provided on the inner panel.
-- Slide the tabs on the front edge and the sides into place.
-- The clips must engage audibly when pressing in.
-- Press the clip in.
- Installation:
- Door
- Clip