Overview - Central Valve: Notes

Fig 1: Exploded View Of Central Valve, Remove/Install Components
GWWA43-10184Courtesy of AUDI OF AMERICA, LLC
  1. Front Left and Rear Right Central Valve
  2. Front Right and Rear Left Central Valve
  3. Shut-Off Valve
    • 12 Nm
    • Through 09/02/2013.
    • To shut off, turn clockwise all the way
    • To open, turn counter-clockwise all the way
  4. Shut-Off Valve Locking Nut
    • 12 Nm
    • Through 09/02/2013.
  5. DRC Line to Rear Left Shock Absorber
    • 14 Nm
    • Green marking
  6. DRC Line to Right Front Shock Absorber
    • 14 Nm
    • White color mark
  7. Locking Element
    • Through 09/02/2013 the central valve with the shut-off valve / central valve is filled.
    • 12 Nm
    • To shut off, turn clockwise all the way
    • To open, turn counter-clockwise all the way
      • From 09/02/2013 the central valve with plug/central valve is not filled.
    • 36 Nm
  8. Locking Element
    • Through 09/02/2013 the central valve with the shut-off valve / central valve is filled.
    • 12 Nm
    • To shut off, turn clockwise all the way
    • To open, turn counter-clockwise all the way
      • From 09/02/2013 the central valve with plug/central valve is not filled.
    • 36 Nm
  9. DRC Line to Left Front Shock Absorber
    • 14 Nm
    • Blue color mark
  10. DRC Line to Rear Right Shock Absorber
    • 14 Nm
    • Yellow color mark
  11. Locking Element
    • Through 09/02/2013 the central valve with the shut-off valve / central valve is filled.
    • 12 Nm
    • To shut off, turn clockwise all the way
    • To open, turn counter-clockwise all the way
      • From 09/02/2013 the central valve with plug/central valve is not filled.
    • 36 Nm
  12. Locking Element
    • Through 09/02/2013 the central valve with the shut-off valve / central valve is filled.
    • 12 Nm
    • To shut off, turn clockwise all the way
    • To open, turn counter-clockwise all the way
      • From 09/02/2013 the central valve with plug/central valve is not filled.
    • 36 Nm
  13. Bolt
    • 20 Nm
  14. Bolt
    • 20 Nm
  15. Retaining Bracket