Overview - Charge Air System
WARNING: This page is about a different car, the 2016 Audi Q5, 2015 Audi Q5, and 2014 Audi Q5. However, it is still accessible from the selected car via links, so may be relevant.
- Charge Air Cooler
- Removing and installing, refer to CHARGE AIR COOLER, REMOVING AND INSTALLING .
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Air Guide Hose
- To charge air cooler
- Must be free of oil and grease before installing
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Bolt
- 9 Nm
- Right Air Guide Pipe
- Bolt
- 9 Nm
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Air Guide Hose
- To turbocharger
- Must be free of oil and grease before installing
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Air Guide Hose
- To the intake manifold
- Must be free of oil and grease before installing
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Not Installed
- Left Air Guide Pipe
- O-Ring
- Replace
- Bolt
- 5 Nm
- Charge Air Pressure Sensor -G31- / Intake Air Temperature Sensor -G42-
- Removing and installing, refer to Charge Air Pressure Sensor -G31 - / Intake Air Temperature Sensor -G42-, REMOVING AND INSTALLING .
- Bushing
- Nut
- 9 Nm
- Rubber Grommet
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Air Guide Hose
- From charge air cooler
- Must be free of oil and grease before installing
- Hose Clamp
- Tightening specification, refer to Fig 2.
- Bolt
- 7 Nm
NOTE:
The hose connections as well as the air guide pipes and hoses must be free of oil and grease before installing.
Secure all hose connections with hose clamps of the same type as those equipped by the factory .
In order to be able to securely mount the air guide hoses on their connectors, spray the screws on the previously used clamps with a rust remover.
Tightening specification for
- Hose clamp -a- = 13 mm wide: 5.5 Nm
- Hose clamp -b- = 9 mm wide: 3.4 Nm