Dynamic Ride Control (DRC), System Pressure Checking
Special Tools And Workshop Equipment Required
- DRC Pressure Tester:VAS6209/2
- Hand Vacuum Pump:VAS6213
:VAS6209/2 Bleeding
Use only approved oil for the bleeding procedure.
The charging device :VAS6209/2 must always be bled the first time it is used.
If the charging device :VAS6209/2 still shows a residual pressure greater than 0.5 bar (7.2 psi) (for example, from a previous reading), bleeding must not be done.
-- To bleed pressure gauge -B- and line section -A-, install special tool as shown in illustration.
The illustration shows bleeding process by extracting hydraulic fluid using a :VAS6213 .
-- Bleed process must be performed until air bubbles are no longer visible in hose -C-.
-- Disconnect hose -C and D- and perform system pressure check.
System Pressure Check Is Performed on Front Shock Absorber of Corresponding Dynamic Ride Control (DRC) Line.
-- Remove the cap from the extract/fill valve and connect the :VAS6209/2 .
-- Read the system pressure on the :VAS6209/2 .
The pressure on the :VAS6209/2 increases slowly and takes approximately two minutes. The DRC system pressure can only be read when the needle on the :VAS6209/2 has finally come to a stop.
-- Disconnect the :VAS6209/2 and install the dust cap.
A small oil leak at the connection that results from connecting or disconnecting the Dynamic Ride Control (DRC) System pressure tester for Audi RS4 :VAS6209/2 is not critical. Avoid repeating measurements because a small quantity of oil is removed from the system every time the DRC system pressure tester for Audi RS4 :VAS6209/2 is connected. Every connection results in a pressure decrease of approximately 0.3 bar (4.35 psi) from the previous reading. Multiple repeated measurements decrease system pressure belo w minimum pressure or failure.
-- If the pressure is not OK, determine the cause and service the system.
Dynamic Ride Control (DRC) System Pressure Values
Pressure values refer to reference temperature of 20 °C (68 °F).
- 20 bar (290.07 psi) = operating pressure
- 19 bar - 20 bar (275.57 - 290.07 psi) = central valve new or as good as new
- 18 bar - 19 bar (261 - 275.57 psi) = normal range of operation, system OK
- < 18 bar (261 bar) = system leaking or not filled completely, air entering system, central valve has no pressure/is empty.