Home >> Audi >> 2014 >> A5 Prestige >> Repair and Diagnosis >> External Pages >> Different car >> Section 1287 (Air Conditioning (Overview) (Coupe)) >> 87 Air Conditioning >> Refrigerant Circuit >> Refrigerant Lines, Disconnecting And Connecting At Condenser >> Refrigerant Lines, Disconnecting And Connecting At Condenser, RS Models >> Removing

Refrigerant Lines, Disconnecting And Connecting At Condenser, RS Models: Removing

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.

-- Turn off the ignition.

-- Discharge the refrigerant circuit. Refer to REFRIGERANT CIRCUIT (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).

-- Remove the air guide for the left auxiliary radiator. Refer to RADIATOR/COOLANT FAN [For transmission(s) 0B6] [For engine(s) CAUA] or RADIATOR/COOLANT FAN [For engine(s) CFSA] or RADIATOR/RADIATOR FAN [For engine(s) CAED, CAEB, CPMB, CPMA] or RADIATOR/COOLANT FAN [For engine(s) CALA] .

-- Remove the bolt -B-.

Fig 1: Identifying Bolt
GWWA87-10397Courtesy of AUDI OF AMERICA, LLC

-- Remove the refrigerant line -A- from the condenser.

-- Remove the bolt -1-.

Fig 2: Identifying Refrigerant Pipe Components
GWWA87-11477Courtesy of AUDI OF AMERICA, LLC

-- Remove the refrigerant pipe -2- from the condenser.

-- Seal the open lines and connections with clean plugs from the :VAS6122  .