LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2014 >> A5 Prestige >> Repair and Diagnosis >> External Pages >> Different car >> Section 1247 (Self-Leveling Suspension (2 Of 2) (Coupe)) >> 43 Self-Leveling Suspension >> Diagnosis And Testing >> Dynamic Ride Control System Pressure Test

Dynamic Ride Control System Pressure Test

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools And Workshop Equipment Required 

Bleed charging device :V.A.S 6209/2 

Use only approved oil for the bleeding procedure.

NOTE:

Charging device :V.A.S 6209/2  must always be bled at initial use.

If charging device :V.A.S 6209/2  still shows a residual pressure greater than 0.5 bar (e.g. from a previous reading), bleeding must not be done.

-- To bleed pressure gauge -B- and line section -A-, install special tool as shown in illustration.

Fig 1: Bleeding Pressure Gauge And Line Section
GWWA43-10070Courtesy of AUDI OF AMERICA, LLC
NOTE:

Illustration shows bleeding process by extracting hydraulic oil with :VAS 6213 

-- Bleed process must be performed until air bubbles are no longer visible in hose -C-.

-- Disconnect hose -C- and -D- and perform system pressure check.

System Pressure Check Is Performed On Front Shock Absorber Of Corresponding DRC Line.

Fig 2: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC

-- Remove the cap from the extract/fill valve and connect the :V.A.S 6209/2  .

-- Read system pressure at :V.A.S 6209/2  .

Fig 3: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC
NOTE:

Pressure increase at :V.A.S 6209/2  occurs slowly and takes approximately 2 minutes. DRC system pressure can only be read when :V.A.S 6209/2  needle has finally come to a stop.

-- Disconnect :V.A.S 6209/2  and install dust cap.

Fig 4: Connecting V.A.S 6209/2 And Remove Dust Cap
GWWA43-10187Courtesy of AUDI OF AMERICA, LLC
NOTE:

Small oil leak which results from connecting or disconnected :V.A.S 6209/2  at connection is not critical. Avoid repeating measurements because a small quantity of oil is removed from the system every time the :V.A.S 6209/2  is connected. Every connection results in a pressure decrease of approximately 0.3 bar from the previous reading. Multiple repeated measurements decrease system pressure below minimum pressure or failure.

-- If the pressure is not OK, determine the cause and service the system.

DRC System Pressure Values 

Pressure Values Refer To Reference Temperature Of 20 °C (68 °F).