Hybrid Battery Refrigerant Shut-Off Valve 1 -N516-, Removing And Installing: Removing
WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.
-- Turn Off The Ignition.
-- Discharge The Refrigerant Circuit. Refer To REFRIGERANT CIRCUIT, DISCHARGING WITH A/C SERVICE STATION , REFRIGERANT CIRCUIT, EVACUATING WITH A/C SERVICE STATION , and REFRIGERANT CIRCUIT, CHARGING WITH A/C SERVICE STATION (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).
-- Free up the clip -2- for the wiring harness on the refrigerant pipe.
-- Remove the bolt -3- and separate the refrigerant pipe -4-.
NOTE:
Ignore items -1, 5 and 6-.
-- Disconnect and remove the connector -3- from the bracket.
-- Remove the union nuts -1 and 2- while counterholding on the connection and remove the Hybrid Battery Refrigerant Shut-Off Valve 1 -N516-.