Battery, Removing And Installing: Removing
-- Turn Off The Ignition And Remove The Key.
TDI (SCR) Vehicles
- After the ignition is switched off, the reducing agent goes from the metering line to the Reducing Agent Injector -N474- and back into the reducing agent active chamber.
- Wait until all the reducing agent has been returned before working in this area. This could take up to 10 minutes after switching off the ignition.
- Only after this is complete can the battery be disconnected. Again, this could take up to 10 minutes after switching off the ignition.
COUPE:
-- Lift the luggage compartment floor and engage it on the body.
-- Remove the nut -1- and remove the cover -2- for the vehicle tool kit.
Sportback:
-- Remove the luggage compartment floor panel cover.
-- Remove the nut -1- and the tool kit mount -2-.
-- If equipped, remove the subwoofer. Refer To Sound System .
NEGATIVE TERMINAL COVER - VERSION I:
-- Remove the tool kit mount -3-.
-- Remove the bolts -A arrows-.
-- Remove the retaining bracket -2- for the vehicle tool kit cover.
-- Release clips -B arrows- using a screwdriver and remove the negative terminal cover -1-.
-- Connect The Battery Charger For Battery Support Mode. Refer To SUBWOOFER -R211-, REMOVING AND INSTALLING .
NEGATIVE TERMINAL COVER - VERSION II:
-- Remove the vehicle tools mount -2-.
-- Remove the bolts -arrows- and remove the bracket -1-.
-- Connect The Battery Charger For Battery Support Mode. Refer To BATTERY, CHARGING WITH BATTERY CHARGER :VAS5900 .
Continuation For All Vehicles:
-- Loosen the nut -4- several turns and remove the battery ground cable terminal clamp from the battery terminal.
-- Remove the cover -3- over the positive terminal.
-- Loosen the nut -2- several turns and remove the battery positive cable terminal with the Fuse Panel A -SA- from the battery terminal.
-- Disconnect the hose -5- for the central venting system.
-- Remove the bolt -6- from the battery bracket -7-.
-- Remove the battery -1- from the battery mount.
-- Remove battery from luggage compartment.
Pollution Risk.
- The Disposal Regulations For Batteries And Sulfuric Acid Must Always Be Followed When Disposing Of Batteries. Refer To BATTERY, CHARGING WITH BATTERY CHARGER :VAS5900 .