LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2014 >> A5 Prestige >> Repair and Diagnosis >> External Pages >> Different car >> Section 10 (1.8L - Turbo Engine Controls - Generic Scan Tool, Engine Code(S): AMB) >> 20 - Fuel supply >> Evaporative Emissions (EVAP) System >> Evaporative Emission (EVAP) canister system, checking for proper seal

Evaporative Emission (EVAP) canister system, checking for proper seal

WARNING: This page is about a different car, the 2006 Audi A4, 2005 Audi A4, 2004 Audi A4, 2003 Audi A4, and 2002 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
  • Secure all hose connections using hose clamps appropriate for the model type .
  • Replace seals and gaskets when performing repair work.

Test sequence 

Specified value: test OK

NOTE:
  • If the accelerator pedal is depressed during the test, the test will be aborted.
  • To repeat the tank leak-tightness test, switch the ignition off, start the engine again, and let it run at idle.

If the specified value is obtained:

If the specified value is not obtained:

Checking fuel supply and tank ventilation systems for leaks 

Fig 1: Releasing Retaining Tabs
GW00014431Courtesy of VOLKSWAGEN UNITED STATES, INC.
Fig 2: Folding Cover Toward Front
GW00014432Courtesy of VOLKSWAGEN UNITED STATES, INC.
Fig 3: Unbolting Cover
GW00014433Courtesy of VOLKSWAGEN UNITED STATES, INC.
Fig 4: Removing Cover Bolts For Locking Flange
GW00014428Courtesy of VOLKSWAGEN UNITED STATES, INC.
NOTE:
  • Leaks at the lines and components of the fuel tank ventilation system can sometimes be located using a non-flammable, environmentally compliant leak detection spray. Initiate the leak diagnosis several times in sequence to build up pressure in the system. At leaking areas, bubbles will form.

If a leak is detected:

NOTE:
  • Due to the form or function of the components, leaking areas may not always be localized by spraying on the leak detection spray. It may be necessary to clamp off the relevant component using Hose Clamps Up To 25mm Dia. and initiate the tank leak detection diagnostic. If the leak is no longer indicated, the component that was clamped off is faulty. If clamped off directly at the leak detection pump and a leak is still indicated, the leak detection pump itself is leaking.

Final procedures 

After the repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory.
  2. If necessary, erase the DTC memory. Refer to Diagnostic Mode 04: Reset/delete diagnostic data .
  3. If the DTC memory was erased, generate readiness code. Refer to Readiness Code .