Home >> Audi >> 2014 >> A5 Premium Plus >> Repair and Diagnosis >> External Pages >> Different car >> Section 1197 (AIR CONDITIONING R1234yf (REFRIGERANT CIRCUIT) (COUPE)) >> 87 Air Conditioning >> Refrigerant Circuit >> Leaks, Finding >> General Information For Finding Leaks On The Refrigerant Circuit

General Information For Finding Leaks On The Refrigerant Circuit

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

Minor leaks can be detected using an electronic leak detector or UV leak detector lamp.

This repair information describes two different methods for detecting leaks in the refrigerant circuit. These methods have been tested and result in success when used correctly.

Many methods for detecting leaks in the refrigerant circuit are offered in the open market. These methods do not always have clear results and if they are not performed exactly to the specification may show several components in the refrigerant circuit as having leaks which do not. Also, refrigerant circuit components can be damaged by some methods.

NOTE:

VW/Volkswagen/Audi does not approve the use of chemicals to seal leaks in the refrigerant circuit (leak stop additives).

Chemicals that seal leaks in the coolant circuit form deposits that affect the function of the A/C system and lead to failure of the A/C system (and the A/C service station).

Chemical materials to seal leaks in the refrigerant circuit react with air or the moisture in the air and form deposits in the refrigerant circuit (and the A/C service station) that lead to malfunctions in the valves and other components that come into contact with such chemicals. These deposits cannot be removed completely from the components, even by cleaning/flushing. It is only possible to service the refrigerant circuit by replacing all the components which come in contact with this material.