Acc, Calibrating, Calibration Procedure With Acc Setting Device:Vas6190: Notes
WARNING: This page does not describe the selected car, but rather 19 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.
Special Tools And Workshop Equipment Required
- Vehicle Diagnostic Tester
- ACC Setting Device:VAS6190
- ACC Adjuster:VAS6190/2
- Wheel Alignment Computer
NOTE:
The :VAS6190 may have to be adapted for the adjustment procedure. Refer to Setting Device Basic Set .
Before driving the vehicle onto the alignment stand, check if there is enough space between the vehicle and the :VAS6190 . The distance between the :VAS6190 and the vehicle must be 120 cm ± 5 cm.
If there is not enough space, drive vehicle the backward on the alignment stand in order to be able to use the space.
- Before beginning the adjustment, check the DTC memory and correct any malfunctions present.
The calibration procedure is described here using the :VAS6190 . However the :VAS6041 and the :VAS6041/1 can also be used.
NOTE:
Do not perform the steps under "Calibration procedure without a previous axle alignment" if an axle alignment has already been performed.