LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> TT Base, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 62 (2.0L - Turbocharger, Supercharger - Engine Code(S): BPY (Roadster) (As Of 10.2010)) >> Turbocharger, Supercharger >> Description And Operation >> Turbocharger Vacuum Diaphragm, Adjusting

Turbocharger Vacuum Diaphragm, Adjusting

WARNING: This page is about a different car, the 2009 Audi TT and 2008 Audi TT. However, it is still accessible from the selected car via links, so may be relevant.

Turbocharger removed 

Special tools and workshop equipment required 

Adjusting 

-- Remove hose -arrow- from vacuum diaphragm on turbocharger.

Fig 1: Disconnecting Hose From Vacuum Diaphragm At Turbocharger
GWWA21-10121Courtesy of AUDI OF AMERICA, LLC

-- Remove securing plate -1- over linkage on turbocharger.

Fig 2: Removing Securing Plate Over Linkage On Turbocharger
GWWA21-10204Courtesy of AUDI OF AMERICA, LLC

-- Loosen lock nut -2-.

Fig 3: Identifying Lock Nut, Linkage From Turbocharger, Vacuum Diaphragm & Turbocharger
GWWA21-10203Courtesy of AUDI OF AMERICA, LLC

-- Adjust the bypass flap -1- using the knurled nut -arrow- so that the flap can still just be turned by hand.

Fig 4: Identifying Bypass Flap Above Linkage Of Vacuum Diaphragm
GWWA21-10122Courtesy of AUDI OF AMERICA, LLC

-- Install the lock nut hand-tight.

-- Connect the VAS 6213, V.A.G 1397A to connection II and the VAS 6342 as depicted in the illustration.

Fig 5: Connecting Hand Vacuum Pump VAS 6213, Turbocharger Tester V.A.G 1397A To Connection II And Pressure Regulator Valve VAS 6342
GWWA21-10120Courtesy of AUDI OF AMERICA, LLC

-- Close the VAS 6342 on lever -1-.

-- Adjust slide ring -1- on the VAS 6213 to -B- position for "Pressure".

Fig 6: Adjusting Slide Ring On Hand Vacuum Pump VAS 6213 To Position For "Pressure"
GWWN24-10282Courtesy of AUDI OF AMERICA, LLC

-- Switch on the V.A.G 1397A and adjust the slide switch to position II.

-- Secure VW 387 on turbocharger -arrow-.

Fig 7: Identifying Dial Gauge VAS 6341/1, Extension VAS 6341/3 And Level Tester VAS 6341/4 On Universal Dial Gauge Holder VW 387
GWWA21-10123Courtesy of AUDI OF AMERICA, LLC
NOTE:

The mm specifications apply to the value read out (includes 1 mm pre-load).

-- Secure the dial gauge 0-30 mm VAS 6341/1 with the dial gauge extension, 30 mm VAS 6341/3 and flat pickup VAS 6341/4 to the VW 387.

-- Set the VAS 6341/1 to 1 mm pre-load at 0 bar.

-- Rotate the VAS 6341/1 display to 0.

-- Check dial gauge for ease of movement.

-- Run the VAS 6213 until the V.A.G 1397A shows 350 +/- 5 mbar.

-- The dial gauge must display between 4.1 mm and 4.33. If not, turn the knurled nut until the value is displayed.

-- Tighten the lock nut hand-tight.

-- Repeat measurement.

-- Reduce pressure to 0 mbar via VAS 6342.

-- Set the VAS 6341/1 to 0.

NOTE:

The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.

-- Run the VAS 6213 until the V.A.G 1397A shows 350 +/- 5 mbar.

-- Read and make a not of the value on dial indicator VAS 6341/1.

-- Operate VAS 6213 until the V.A.G 1397A displays 650 mbar to 700 mbar.

-- Reduce the pressure to 350 +/- 5 mbar using the VAS 6342.

-- Read and make a not of the value on the VAS 6341/1.

-- Add value 1 and 2 and divide by 2.

-- The result (mean value) must be 5 +/- 0.25 mm.

-- If the result (mean value) is not 5 +/- 0.25 mm, correct the adjustment, tighten lock nut hand-tight and repeat the measurement.

-- If the result (average) is 5 +/- 0.25 mm, tighten the lock nut and secure with sealing wax. Sealing wax.

-- Secure securing plate -1- over vacuum diaphragm linkage.

Fig 8: Removing Securing Plate Over Linkage On Turbocharger
GWWA21-10204Courtesy of AUDI OF AMERICA, LLC