LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> TT Base, 2D Convertible >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel Supply System (Roadster) >> Fuel Supply >> Diagnosis And Testing >> Leak Detection Test, Performing

Leak Detection Test, Performing

Special tools and workshop equipment required 

Diagnostic leak test occurs in "Guided Fault Finding" using the vehicle diagnostic tester.

Checking Fuel Supply and Tank Ventilation Systems for Leaks 

NOTE:

The following describes individual areas in the fuel supply and ventilation systems where leaks are possible. After repairing a possible leak, perform a leak test to ensure that leak was successfully repaired.

-- Turn off ignition.

-- Check whether the fuel filler cap of the fuel tank was completely sealed for the test.

-- Check whether seal of fuel filler cap was damaged or crimped. Replace if necessary.

-- Remove rear seat bench. Refer to Removal and Installation .

-- Unclip catches -arrows- of right connector flange cover.

Fig 1: Identifying Cover From Fuel Delivery Unit
GWWA20-1206Courtesy of AUDI OF AMERICA, LLC
NOTE:

Observe installation notes for locking flanges FUEL DELIVERY UNIT  and FUEL DELIVERY UNIT .

AWD Vehicles: 

-- Unclip the retainers -arrows- of the cover for left sealing flange.

Fig 2: Identifying Cover From Fuel Delivery Unit
GWWA20-1216Courtesy of AUDI OF AMERICA, LLC
NOTE:

Follow the installation instructions for the locking flange Fuel Level Sensor 2 -G169- .

All Vehicles: 

-- Check sealing rings seals under locking flanges are OK and lock rings are properly tightened on fuel tank. Also check the fuel line connections.

-- Visually check all wires and hose connections of fuel supply system and replace leaking lines, for example:

NOTE:

Leaks at lines and components of the tank system can sometimes be located using a nonflammable, environmentally compliant leak detection spray. For this, initiate leak diagnostic several times in sequence to build up pressure in the system. At leaking areas, bubbles will form.

-- Perform a visual inspection on the fuel system components and tank ventilation system:

NOTE:

Due to the form or function of the components, leaking areas may not always be localized by spraying on leak detection spray. It may be necessary to clamp off the relevant component using 3094 and initiate tank leak detection diagnostic. If the leak is no longer indicated, the component that was clamped off is faulty. If clamped off directly at the leak detection pump and a leak is still indicated, the leak detection pump itself is leaking.