Home >> Audi >> 2012 >> S5 4.2, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 605 (2.0L - Turbocharger & Supercharger - Engine Code(S): CAEB, CAED, CPMA & CPMB (Sedan)) >> 21 Turbocharger, Supercharger >> Turbocharger >> Turbocharger Vacuum Diaphragm, Adjusting

Turbocharger Vacuum Diaphragm, Adjusting

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2016 Audi A4 Quattro, 2016 Audi A4, 2015 Audi A4 Quattro, 2014 Audi A4 Quattro, and 2013 Audi A4. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

This procedure description is only for 1.8L engines.

Fig 1: Identifying Special Tools - Vacuum Diaphragm For Turbocharger, Adjusting
GWWG21-10000Courtesy of AUDI OF AMERICA, LLC

Special tools and workshop equipment required 

Special tools and workshop equipment required 

Adjusting

NOTE:

It is necessary to adjust the diaphragm only if it has been removed.

-- Pre-adjust bypass flap -1- via nut -arrow- so flap can still just be turned by hand.

Fig 3: Identifying Bypass Flap Above Linkage Of Vacuum Diaphragm
GWWA21-10122Courtesy of AUDI OF AMERICA, LLC

-- Secure the Dial Gauge Holder VW387 onto the turbocharger -arrow-.

Fig 4: Securing Dial Gauge Onto Turbocharger -Arrow-
GWWA21-10123Courtesy of AUDI OF AMERICA, LLC
NOTE:

The mm specifications apply to the value read out (includes 1 mm pre-load).

The Dial Gauge Set - Dial Gauge VAS6341/1 with Dial Gauge Set - Extension - 30mm VAS6341/3 must align with the linkage on the vacuum diaphragm.

-- Secure the Dial Gauge Set - Dial Gauge VAS6341/1 with the Dial Gauge Set - Extension - 30mm VAS6341/3 and Dial Gauge Set - Flat Pickup VAS6341/4 to the Dial Gauge Holder VW387.

-- Set the Dial Gauge Set - Dial Gauge VAS6341/1 to 1 mm pretension.

-- Turn the Dial Gauge Set - Dial Gauge VAS6341/1 display to 0.

-- Check dial gauge for ease of movement.

-- Turn the nut -1- approximately 7 turns in -direction of arrow-.

Fig 5: Adjusting Dial Gauge
GWWA21-10406Courtesy of AUDI OF AMERICA, LLC

-- Turn the nut -2- in -direction of arrow- until the dial gauge shows 7 mm.

-- Hand-tighten the nut -1-.

-- Set the Dial Gauge Set - Dial Gauge VAS6341/1 to 1 mm pretension.

-- Turn the Dial Gauge Set - Dial Gauge VAS6341/1 display to 0.

-- Connect the Hand Vacuum Pump VAS6213, the Turbocharger Tester Kit VAG1397A to connection II and the Seal Installer - Crankshaft VAS6213 as shown in the illustration.

Fig 6: Connecting VAS6213, VAG1397A To Connection II And VAS6342
GWWA21-10120Courtesy of AUDI OF AMERICA, LLC

-- Switch the Turbocharger Tester Kit VAG1397A and set the slide switch to position II.

-- Close the Pressure Control Valve VAS6213 on the lever -1-.

-- Set the slide ring -1- on the Hand Vacuum Pump VAS6213 in position -B- for "pressure".

Fig 7: Adjusting Hand Vacuum Pump Slide Ring
GWWN24-10282Courtesy of AUDI OF AMERICA, LLC
NOTE:

The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.

-- Operate the Hand Vacuum Pump VAS6213 until the Turbocharger Tester Kit VAG1397A displays 460 +/- 5 mbar.

NOTE:

If 460 ± 5 mbar is exceeded, then the measuring must be started again from the beginning.

-- Read and note the value on the Dial Gauge Set - Dial Gauge VAS6341/1.

-- Operate the Hand Vacuum Pump VAS6213 until the Turbocharger Tester Kit VAG1397A displays 650 mbar to 700 mbar.

-- Reduce the pressure to 460 +/- 5 mbar via Pressure Control Valve VAS6213.

NOTE:

If 460 ± 5 mbar is not reached, then the measuring must be started again from the beginning.

-- Read and note the value on the Dial Gauge Set - Dial Gauge VAS6341/1.

-- Add value 1 and 2 together and divide by two.

-- The result (mean value) must be 5 +/- 0.5 mm.

-- If the value is greater, then lower the pressure to 0 bar, loosen the nut -1- and turn the nut -2- a half a turn and then tighten the nut -1- hand-tight.

Fig 8: Adjusting Dial Gauge
GWWA21-10406Courtesy of AUDI OF AMERICA, LLC

-- Set the Dial Gauge Set - Dial Gauge VAS6341/1 to 1 mm pretension.

-- Turn the Dial Gauge Set - Dial Gauge VAS6341/1 display to 0 and repeat the measurement.

-- If the average value is 5 ± 0.5 mm, then tighten the lock nut and repeat the measurement.

-- If the average value is 5 ± 0.5 mm, then secure the nuts with sealing wax. Sealing wax.

-- Secure the new securing plate -1- over vacuum diaphragm linkage.

Fig 9: Identifying Securing Plate On Linkage To Turbocharger
GWWA21-10204Courtesy of AUDI OF AMERICA, LLC

Tightening Specifications