LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> S5 4.2, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 1311 (Turbocharger, Supercharger (Servicing) [CABB, CABA, CABD, CAEA, CAEB, CDHB, CDNB, CDNC, CDHA, CDZA, CADA, CCUA, CFKA, CPMA, CAED, CPMB, CHJA, CPEA] (Cabriolet)) >> 21 Turbocharger, Supercharger >> Charge Air System >> Charge Air System, Checking For Leaks >> Procedure

Charge Air System, Checking For Leaks: Procedure

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2017 Audi A5 Quattro, 2016 Audi A5 Quattro, 2015 Audi A5 Quattro, 2014 Audi A5 Quattro, and 2014 Audi A5. However, it is still accessible from the selected car via links, so may be relevant.

-- Follow the guidelines for clean working conditions. Refer to GUIDELINES FOR CLEAN WORKING CONDITIONS .

-- Remove the front noise insulation. Refer to NOISE INSULATION .

-- Loosen the hose clamp -arrow-, remove the air duct hose and move it to the side.

GWWA21-11023Courtesy of AUDI OF AMERICA, LLC

-- Depending on the hose diameter, insert the :VAG1687/10  , :VAG1687/11  or :VAG1687/12  in the air guide hose -1- and secure with a hose clamp.

GWWA21-10178Courtesy of AUDI OF AMERICA, LLC

-- Connect the : VAG1687  as shown.

Prepare the :VAG1687  as follows:

GWWV21-0168Courtesy of AUDI OF AMERICA, LLC

-- Completely remove the pressure regulating valve -2- and close the valves -3 and 4-.

-- Connect the :VAG1687  to compressed air -1- with a commercially available intermediate piece.

-- Drain the water in the viewing glass via the water drain plug -6-.

-- Open the valve -3-.

CAUTION:

- Never set the test pressure specified.

-- Set the pressure to 0.2 bar (2.9 psi) using the pressure regulating valve -2-.

-- Open the valve -4- and wait until the test circuit is filled. Regulate the pressure to 0.2 bar (2.9 psi) again if necessary.

-- Check the charge air system for leaks by listening, feeling and using commercially available leak detection spray or the Ultrasonic Tester:VAG1842S  . Refer to the Owner's Manual for information on using the :VAG1842S  .

TIP: 

A small quantity of air dissipates via the valves in the engine. For this reason a pressure retention test is not possible.