LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> Q7 3.0 TDI >> Repair and Diagnosis >> External Pages >> Different car >> Section 48 (4.2L - Crankshaft & Cylinder Block - Engine Code: Bar) >> 13 Crankshaft, Cylinder Block >> Diagnosis And Testing >> Connecting Rod, Measuring Radial Clearance

Connecting Rod, Measuring Radial Clearance

WARNING: This page is about a different car, the 2010 Audi Q7, 2009 Audi Q7, 2008 Audi Q7, and 2007 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

-- Remove connecting rod bearing caps.

-- Clean bearing caps and journals.

-- Place Plastigage® over entire width of bearing journal or into bearing shells.

-- Install connecting rod bearing cap and tighten to 60 Nm. Do not turn crankshaft.

-- Remove connecting rod bearing caps again.

-- Compare width of Plastigage® with measuring scale.

Radial clearance:

-- Replace bolts for connecting rod bearings.