LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2012 >> Q7 3.0 TDI >> Repair and Diagnosis >> External Pages >> Different car >> Section 15 (3.0L - Cooling System - Engine Code: CATA) >> 19 Cooling System >> Coolant Pumps And Coolant Thermostat >> Connecting Piece With Coolant Thermostat, Removing And Installing

Connecting Piece With Coolant Thermostat, Removing And Installing

WARNING: This page is about a different car, the 2011 Audi Q7, 2010 Audi Q7, and 2009 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Removal

Fig 1: Identifying Bolt -1-, EGR Coolant Thermostat And Connection
GWWA19-10784Courtesy of AUDI OF AMERICA, LLC

-- Drain the coolant. Refer to COOLANT, DRAINING AND FILLING .

-- Remove the ribbed belt from the tensioner. Refer to RIBBED BELT, REMOVING AND INSTALLING .

-- Remove the bolt -1- and disconnect the exhaust gas recirculation coolant thermostat and connection from the connection.

NOTE:

Ignore -items 2 and 3-.

-- Loosen the clamp -1- and remove the coolant hose.

Fig 2: Identifying Hose Clamp -1- And Bolts -Arrows-
GWWA19-10786Courtesy of AUDI OF AMERICA, LLC

-- Remove the bolts -arrows- and the coolant thermostat with the connection.

Installation

Install in reverse order of removal. Note the following:

NOTE:

Replace the o-rings.

Secure all hose connections with hose clamps of the same type as those equipped by the factory. .

-- Clean the sealing surface.

-- Install the ribbed belt. Refer to RIBBED BELT, REMOVING AND INSTALLING .

-- Fill the coolant, refer to COOLANT, DRAINING AND FILLING .