EGR Cooler Pump
Removing
-- Carefully pull the engine cover -arrows- off the 4 bolts one after the other.
-- Drain the coolant. Refer to COOLING SYSTEM, DRAINING AND FILLING .
-- Disconnect the connector -2-.
-- Remove the bolts -1-.
-- Remove the coolant hoses, to do this, loosen the hose clamps -arrows-.
-- Remove the exhaust gas recirculation (EGR) cooler pump -V400- with the engine lifting eye.
-- Remove the bolts -arrows- and remove the exhaust gas recirculation (EGR) cooler pump from the engine lift eyelet.
Installing
Install in reverse order of removal. Note the following:
- Tightening specifications, refer to Exhaust Gas Recirculation Cooler Pump -V400- OVERVIEW .
NOTE:
Secure all hose connections with hose clamps appropriate for the model.
-- Fill with coolant FILLING .