Refrigerant Lines For Battery Cooling Module In Luggage Compartment, Removing And Installing: Installing
Installation is carried out in the reverse order while observing the following.
Follow the instructions for installing the O-rings. Refer to REFRIGERANT CIRCUIT SEALS .
Following attachment, check routing of refrigerant lines. They must be inserted in holders provided and not make contact with other components.
-- Replace the O-ring seals -4-. Allocate correct version.
-- Clean the refrigerant line connections -3 and 5- and inspect them for damage.
-- Make sure the O-rings -4- sit correctly inside the grooves of the respective mount.
-- Check the alignment pin -2- (not present on all connections) for damage and make sure that it is seated correctly.
-- Tighten the bolts -1-.
-- Install the remaining removed components.
-- Evacuate the refrigerant circuit and fill it. Refer to USING SERVICE STATION . For additional information, refer to OVERVIEW - REFRIGERANT CIRCUIT, NOT OPENING THE REFRIGERANT CIRCUIT, VEHICLES WITHOUT HIGH VOLTAGE SYSTEM and OVERVIEW - REFRIGERANT CIRCUIT, OPENING THE REFRIGERANT CIRCUIT, VEHICLES WITHOUT HIGH VOLTAGE SYSTEM (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).
-- Electrical connections and routing. Refer to the appropriate SYSTEM WIRING DIAGRAM.
-- Energize the power supply to the high voltage system. Refer to HIGH VOLTAGE SYSTEM, RE-ENERGIZING .
Restart the high voltage system
Risk of electrocution
Death or serious bodily injury by electric shock
- The high voltage system may only be restarted by qualified personal (Audi high voltage technicians).
- Make sure the vehicle is energized using the "Guided Fault Finding" on the Vehicle Diagnostic Tester.
- The qualified personal (Audi high voltage technician) restarts the vehicle.
- The Audi high voltage technician should put a sign on the vehicle to identify it as a high voltage vehicle.
Restart the high voltage system:
Connect the vehicle diagnostic tester.
Select the Guided Fault Finding mode.
Using the GO TO button, select the following menu commands
Function/Component Selection
Body
Electrical Equipment
OBD-capable systems
8C - Battery Regulation Control Module -J840
8C - Battery Regulation Control Module, functions
51 - High voltage restart
-- Turn on the ignition.
-- Check the DTC memory for the Climatronic Control Module -J255- display and control head and the A/C Compressor Control Module -J842- and, if necessary, erase the displayed faults using the Vehicle Diagnostic Tester in the "Guided Fault Finding" function.
-- Operate the A/C system after filling the refrigerant circuit. Refer to A/C SYSTEM, STARTING OPERATION AFTER FILLING REFRIGERANT CIRCUIT .
Observe the information regarding operating the A/C system after filling. Refer to A/C SYSTEM, OPERATING AFTER CHARGING , (Refrigerant R134a, Servicing; A/C System, General Information). After charging the A/C system before activating the A/C system.