Connecting Rod, Measuring Axial Clearance
WARNING: This page is about a different car, the 2009 Audi TT and 2008 Audi TT. However, it is still accessible from the selected car via links, so may be relevant.
Special tools and workshop equipment required
- Feeler gauge
Procedure
-- Measure with feeler gauge.
Axial clearance:
- New: 0.05 to 0.31 mm.