O-Ring Seals
These rings seal off the connection points between individual components of the refrigerant circuit.
Only O-rings that are resistant to refrigerant R134a and refrigerant oil must be installed. Make sure they are original replacement parts.
O-ring seals:
-- Always use only once.
-- Make sure diameters -a and b- are correct.
-- Coat with refrigerant oil before installing. Refer to REFRIGERANT CIRCUIT - 1 , REFRIGERANT CIRCUIT - 2 , REFRIGERANT CIRCUIT GENERAL INFORMATION R134a , REFRIGERANT CIRCUIT R134a (vehicle-specific repair information) and the parts information.
The color coding of refrigerant circuit O-rings with R134a has been discontinued. Black and colored O-rings are used. Refer to the parts information and REFRIGERANT CIRCUIT - 1 , REFRIGERANT CIRCUIT - 2 , REFRIGERANT CIRCUIT GENERAL INFORMATION R134a , REFRIGERANT CIRCUIT R134a (vehicle-specific repair information).