LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2011 >> Q5 3.2 >> Repair and Diagnosis >> Engine Mechanical >> Starter >> Battery & Generator >> 27 Starter, Generator And Cruise Control >> Battery, Charging >> Battery Charger VAS5900 >> Battery Charger VAS5900 SUPPORT MODE

Battery Charger VAS5900 SUPPORT MODE

General Information

The support mode provides the vehicle electrical system with voltage when the Battery -A- is removed or disconnected.

For more information. Refer to the Battery Charger VAS5900 Operating Instructions.

The support mode is used for the following situations:

WARNING:

Risk of injury. Follow all warning messages and safety precautions. Refer to WARNINGS AND SAFETY PRECAUTIONS .

WARNING:

Do not check or charge a Battery -A- when the visual indicator has >>no color or is bright yellow<<. Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required 

Procedure 

CAUTION:
  • The polarity protection of the charger clamps is not active in the operation mode "charging severely discharged batteries/Support mode". Connect the charger clamps to the battery terminals correctly according to polarity!
  • It can result in sparks due to short circuit.
  • This constitutes an explosion risk.
  • Do not touch START / STOP  button when battery cables are incorrectly connected! The Battery Charger VAS5900 can become damaged.

-- Remove the Battery -A-. Refer to Battery -A-, REMOVING AND INSTALLING, VEHICLES WITH HIGH VOLTAGE SYSTEM .

-- Connect the Battery Charger VAS5900 to the power supply. The last selected mode is shown on the display. Refer to Battery Charger VAS5900 DEVICE DESCRIPTION .

CAUTION:

Whenever the Battery -A- is removed, be careful to prevent contact between the connected charge clamp on the positive terminal and the body ground. Likewise prevent contact between the battery terminals.

-- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

NOTE:

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

-- Connect the black charge terminal (-) to the negative terminal of the Battery -A- /negative connector.

-- Press the START/STOP  button for about 5 seconds. The menu selection "Charging severely discharged batteries/Support mode" is activated.

-- Press the corresponding ↑  -button or ↓  button to adjust the battery voltage (6 V/12 V/24 V).

NOTE:

If no button is touched within five seconds, the Battery Charger VAS5900 will return to the main menu (operating mode selection).

-- Select the battery voltage by pressing the START/STOP  button.

Then the inquiry about the correct polarity of the charging clamps is made.

-- Check correct polarity connection of charger clamps.

-- Confirm charging clamps are connected to correct poles via START/STOP  button.

The Battery Charger VAS5900 starts the Battery -A- support mode.

End the Battery Support Mode

-- Press the START/STOP  -button.

-- Remove the charging clamps from the battery terminals.

-- Disconnect the Battery Charger VAS5900 from the power.