Home >> Audi >> 2011 >> Q5 2.0T >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating, Ventilation & Air Conditioning (2 Of 2) (As Of 06.2014) >> 87 Air Conditioning >> Battery Cooling Module >> Hybrid Battery Refrigerant Shut-Off Valve 1 -N516-, REMOVING AND INSTALLING >> Installing

Hybrid Battery Refrigerant Shut-Off Valve 1 -N516-, REMOVING AND INSTALLING: Installing

Installation is carried out in the reverse order while observing the following.

NOTE:

Follow the instructions for installing the O-rings. Refer to REFRIGERANT CIRCUIT SEALS .

Following attachment, check routing of refrigerant lines. They must be inserted in holders provided and not make contact with other components.

-- Replace the O-ring seals. For the correct version .

-- Install the union nuts -1 and 2- all the way by hand and then tighten them.

NOTE:

Make sure when tightening the union nuts that the refrigerant lines are not tensioned.

-- Evacuate the refrigerant circuit and fill it. Refer to USING SERVICE STATION (Refrigerant R134a, Servicing; Refrigerant Circuit, Using Service Station).

-- Turn on the ignition.

-- Check the DTC memory for the Climatronic Control Module -J255- display and control head and the A/C Compressor Control Module -J842- and, if necessary, erase the displayed faults using the Vehicle Diagnostic Tester in the "Guided Fault Finding  " function.

-- Operate the A/C system after filling the refrigerant circuit. Refer to A/C SYSTEM, STARTING OPERATION AFTER FILLING REFRIGERANT CIRCUIT .

NOTE:

Observe the information regarding operating the A/C system after filling. Refer to A/C SYSTEM, OPERATING AFTER CHARGING , (Refrigerant R134a, Servicing; A/C System, General Information). After charging the A/C system before activating the A/C system.