Home >> Audi >> 2011 >> A5 2.0T >> Repair and Diagnosis >> External Pages >> Different car >> Section 618 (Heating, Ventilation & Air Conditioning (2 Of 2) (As Of 06.2014)) >> 87 Air Conditioning >> Additional Components For Control And Regulation >> Humidity Sensor In Fresh Air Intake Duct -G657- FUNCTION

Humidity Sensor In Fresh Air Intake Duct -G657- FUNCTION

WARNING: This page does not describe the selected car, but rather 13 other vehicles, including the 2017 Audi SQ5, 2017 Audi Q5, 2016 Audi SQ5, 2016 Audi Q5, and 2015 Audi SQ5. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

There are different versions depending on the vehicle date of manufacture and the A/C system version ("Basis" or "Convenience") is installed. The "Basis" A/C system does not have a humidity sensor in the Humidity Sensor in Fresh Air intake Duct -G657- /Air Quality Sensor -G238- until the MY 2012 changeover. From MY 2012 it has a humidity sensor in Humidity Sensor in Fresh Air intake Duct -G657- without an Air Quality Sensor -G238- (black housing). From MY 2012, the "Convenience" A/C system has an Air Quality Sensor -G238- without a Humidity Sensor in Fresh Air intake Duct -G657-. From this change, a Humidity Sensor in Fresh Air intake Duct -G657- is installed with an Air Quality Sensor -G238- (brown housing).

Only vehicles with the "Convenience" A/C system have an Air Quality Sensor -G238- without a Humidity Sensor in Fresh Air intake Duct -G657- (from start of production up the changeover) .

From MY 2012, the vehicle version was changed-over as a running change beginning with Audi A4 and Audi A5. Refer to DISPLAY AND CONTROL HEAD LOCATION . Vehicles, built before the changeover and with the "Convenience" A/C system, have an Air Quality Sensor -G238- (not installed on the "Basis" version). For vehicles built since this changeover (and for the Audi Q5 Hybrid), a Humidity Sensor in Fresh Air intake Duct -G657- is installed on the "Basis" version and a Humidity Sensor in Fresh Air intake Duct -G657- with the Air Quality Sensor -G238- is installed on vehicles with the "Convenience" version.

Fig 1: Identifying Air Quality Sensor And Humidity Sensor
GWWA87-10906Courtesy of AUDI OF AMERICA, LLC

This is how to tell the difference: the Humidity Sensor In Fresh Air Intake Duct -G657- with an Air Quality Sensor -G238- has a brown housing (running change from MY 12). For the Humidity Sensor in Fresh Air intake Duct -G657- version without the Air Quality Sensor -G238-, the housing is black (running change from MY 2012). For the Air Quality Sensor -G238- version without a Humidity Sensor in Fresh Air intake Duct -G657-, the housing is black and the Humidity Sensor in Fresh Air intake Duct -G657- -3- is not present (gradual discontinuation from MY 2012).