Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 977 (Climate Control System (Service Information - (Refrigerant Circuit) CAEB, CGXB, CEUC, CTUA, CEUC, CAED, CHJA, CPNB, CRDB, CPNB, CREC, CTGE, CYNB, CWUC, CREH, CWUB)) >> Air Conditioning >> Refrigerant Circuit >> A/C System, Starting Operation After Filling Refrigerant Circuit >> Starting Engine With Empty Refrigerant Circuit When Unavoidable

Starting Engine With Empty Refrigerant Circuit When Unavoidable

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:

There is a risk of damaging the mechanically-driven A/C compressor if the engine runs when the refrigerant circuit is not filled. .

  • The A/C compressor is always driven when engine is running; there is no magnetic clutch. Engine is therefore not to be started unless refrigerant circuit has been properly assembled.
  • For example; if the refrigerant lines are not connected to A/C compressor, the A/C compressor may heat up so much when the engine is running that the A/C compressor will be damaged by internal heat generation.
  • Only start the engine when the refrigerant circuit is filled.
  • Do not start the engine while evacuating the refrigerant circuit or when the circuit is already evacuated. .
  • The engine should not be run for longer than absolutely necessary.
NOTE:

The A/C compressor has an "Internal oil circuit" to ensure the A/C compressor is not damaged when refrigerant circuit is empty. There must be a residual amount of refrigerant oil in the A/C compressor for this.

NOTE:

If only the refrigerant was extracted (the A/C compressor was not removed), it is assured that there is enough refrigerant oil is in the A/C compressor to maintain the lubrication of the A/C compressor for a short operating period due to the design of the refrigerant circuit.