Data Bus on Board Diagnostic Interface -J533-, REMOVING AND INSTALLING: Removing
-- Remove the rear bench seat. Refer to REAR SEAT BENCH/SINGLE SEAT, REMOVING AND INSTALLING . .
-- Fold back the front of the insulation mat.
-- Remove the nuts -arrows-, if equipped.
-- Remove the Data Bus on Board Diagnostic Interface -J533- -3- from the threaded pins.
-- Disconnect the connector -5- and the connector -4- for the fiber-optic cable.
If the ground cable -1- is above the fastener on the Data Bus on Board Diagnostic Interface -J533- as illustrated, then it must be loosened on the ground distributor -2-.
-- Seal the open wiring harness connector -2- of the fiber-optic cable with the :VAS6223/9 -1-.
The protective cap prevents contamination of or mechanical damage to the front surface of the fiber-optic cable which would impair light transmission.
-- Press the retaining tab -1- to disconnect the connector, turn the retaining bracket in direction of -arrow- and remove the connector.