Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 965 (Climate Control System (General Information) (Refrigerant Circuit)) >> 87 Air Conditioning >> Refrigerant Circuit General Information >> Refrigerant Circuit Components Allocation, High And Low Pressure Sides >> Receiver/Dryer

Refrigerant Circuit Components Allocation, High And Low Pressure Sides: Receiver/Dryer

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

The receiver/dryer collects the fluid drops and then directs them in an uninterrupted stream to the expansion valve. Moisture which has entered the refrigerant circuit during repairs will be collected by the desiccant bag in the receiver/dryer.

GWWN87-0336Courtesy of AUDI OF AMERICA, LLC
NOTE:

Replace the receiver/dryer if refrigerant circuit has been open for a long time (beyond the normal repair time) and moisture has penetrated inside, or if required due to a specific complaint. Refer to REFRIGERANT CIRCUIT COMPONENTS, REPLACING .

Only remove sealing plugs shortly before installation.

A desiccant bag in an unsealed receiver/dryer becomes saturated with moisture after a short period of time and unusable.

When installing, note arrow for direction of flow if necessary.

Depending on the version of the refrigerant circuit, the receiver/dryer is also installed (integrated) either on the condenser or inside the condenser. Refer to REFRIGERANT CIRCUIT (vehicle-specific repair information). (vehicle-specific repair information) and the parts information.

The procedure is different for each complaint depending on the version of the receiver/dryer and the dryer cartridge. If the receiver/dryer, for example, is attached to the condenser, then it can be replaced complete with the drying cartridge. If the receiver/dryer, for example, is inside the condenser, then the dryer cartridge, and any possible additional filters, can be replaced separately, on most versions. If the receiver/dryer is inside the condenser and there is absolutely no way to replace the reservoir or the dry cartridge individually, then the entire condenser must be replaced. Refer to REFRIGERANT CIRCUIT

Depending on the construction of the refrigerant circuit, the receiver can also be secured onto the condenser. Refer to REFRIGERANT CIRCUIT