LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 965 (Climate Control System (General Information) (Refrigerant Circuit)) >> 87 Air Conditioning >> A/C System, General Information >> Refrigerant Circuit, General Precautions >> Refrigerant Circuit, Cleaning

Refrigerant Circuit, Cleaning

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Cleaning the refrigerant circuit with refrigerant R134a (flushing with refrigerant R134a). Refer to REFRIGERANT CIRCUIT, CLEANING (FLUSHING) WITH REFRIGERANT R134A . (Or blow out with compressed air and nitrogen). Refer to REFRIGERANT CIRCUIT, FLUSHING WITH COMPRESSED AIR AND NITROGEN . In the event of:

-- Moisture or dirt has gotten into the refrigerant circuit, for example, after a crash.

-- Refrigerant oil is dark and viscous.

-- There is too much refrigerant oil in the refrigerant circuit after replacing the compressor.

-- The A/C compressor had to be replaced due to "internal" damage (for example, noises or no output).

NOTE:

When flushing components with compressed air and nitrogen, extract the gas mixture escaping from the components thoroughly via an existing exhaust-extraction ventilation system (workshop extraction system).