LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 963 (Air Conditioning) >> 87 Air Conditioning >> Refrigerant Circuit >> Leaks, Finding >> Leaks, Determining With A Pressure Test, With Nitrogen Or Compressed Air

Leaks, Determining With A Pressure Test, With Nitrogen Or Compressed Air

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

Small leaks (less than 100g (3.5 oz) of refrigerant loss per year) are not often detected with the vacuum test or with the pressure test. The incoming air or the amount of nitrogen flowing out is too small to be able to locate the faulty location based on noise.

Leaks on the refrigerant circuit that are greater than 100g (3.5 oz) of refrigerant loss each year are also not always detectable with the vacuum test or with the pressure test, depending on the ambient conditions (ambient noise, leak location etc.). The incoming air and the quantity of nitrogen flowing out is currently too small to detect any noise and locate the faulty location.

Larger leaks on the refrigerant circuit (for example an impact from a rock on the condenser, greater than 100g (3.5 oz) of refrigerant loss per year) can be detected for example from noise, using the vacuum test or the pressure test. Refer to REFRIGERANT CIRCUIT, EVACUATING .

A large leak can be identified if a maximum of pressure of 15 bar (217.55 psi) can be generated in the refrigerant circuit using clean, dry compressed air or nitrogen. Refer to REFRIGERANT CIRCUIT, FLUSHING WITH COMPRESSED AIR OR NITROGEN . If the leak is large enough, the sound of escaping air or gas can be heard at the location of the leak.

Tools Required: 

-- Perform a pressure test. Refer to Refrigerant Circuit, Evacuating .