Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 963 (Air Conditioning) >> 87 Air Conditioning >> Refrigerant Circuit >> Components, Replacing >> Leaking Or Damaged Areas, Replacing, Empty Refrigerant Circuit Except A/C Compressor And Receiver/Dryer

Leaking Or Damaged Areas, Replacing, Empty Refrigerant Circuit Except A/C Compressor And Receiver/Dryer

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

The Refrigerant Circuit Was Completely Empty (for Example with Larger Leak or Cracked Hose)

NOTE:

In the event of only a minor leak with slow escape of refrigerant (for example at a small leakage point), the amount of refrigerant oil lost and the amount of moisture penetrating after servicing is not sufficient to influence operation of the air conditioner.

The operations marked* are only to be implemented in case of a major leak (for example following an accident).

-- Remove the faulty component.* Refer to REFRIGERANT CIRCUIT [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB]

-- Clean the refrigerant circuit (flush with refrigerant R1234yf). Refer to REFRIGERANT CIRCUIT, CLEANING .

Electrically-Driven A/C Compressor 

-- Remove the electrically-driven A/C compressor and clean (flush with refrigerant R1234yf)*. Refer to REFRIGERANT CIRCUIT, CLEANING  and A/C COMPRESSOR

Mechanically Driven A/C Compressor 

-- Remove A/C compressor.* Refer to A/C COMPRESSOR

-- Remove the oil drain plug -B / D- from the A/C compressor -A-.*

GWWA87-10615Courtesy of AUDI OF AMERICA, LLC
NOTE:

The versions of the oil drain plug -B / D- and the seal -C / E- are different (depending on the manufacturer of the A/C compressor). Refer to A/C COMPRESSOR

When installing the oil drain plug -B / D- note the tightening specification (depending on the manufacturer of the A/C compressor and the version of the oil drain plug) on "Denso" and "Delphi" A/C compressor is for example installed on the oil drain plug (tightening specification currently 30 Nm on "Denso" and 15 Nm on "Delphi" A/C compressor). On "Sanden" or "Zexel- / Valeo" A/C compressors an oil drain plug or a seal is installed depending on the version on the oil drain plug (tightening specification currently 10 Nm).

On Denso A/C compressors for example a seal -E- is installed on the oil drain plug -D-. Refer to A/C COMPRESSOR

On Sanden A/C compressors for example a seal -C- is installed on the oil drain plug -B-. Refer to A/C COMPRESSOR . Refer to A/C COMPRESSOR for the tightening specification.

If the seals (seal or O-ring) that are installed on the oil drain plug are not available as a replacement part, the removed seals may be used as an exception (check for damage before installing). If the removed seal is damaged or deformed if necessary replace with a commercially available component.

After charging the refrigerant circuit check the installed oil drain plug for leaks for example using an electronic leak detector.

To accelerate drainage of refrigerant oil, turn the A/C compressor via the belt pulley or the A/C clutch plate, for example.

-- Drain the old refrigerant oil from the A/C compressor. Refer to A/C COMPRESSOR, REPLACING WITHOUT THE NEED FOR FLUSHING REFRIGERANT CIRCUIT .

All Vehicles 

-- Fill the specified complete oil quantity in the A/C compressor or the circuit. Refer to A/C COMPRESSOR, REPLACING WITHOUT THE NEED FOR FLUSHING REFRIGERANT CIRCUIT  and REFRIGERANT CIRCUIT, CHARGING and TECHNICAL DATA [For transmission(s) 0BK] or TECHNICAL DATA [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB] (The approved refrigerant oil and capacity for the refrigerant oil can be found in the vehicle-specific repair information).

NOTE:

Then fill A/C compressor with quantity of new refrigerant oil corresponding to quantity of refrigerant oil in replacement A/C compressor.* Refer to TECHNICAL DATA [For transmission(s) 0BK] or TECHNICAL DATA [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB]

Use the different refrigerant oils and quantities for the different A/C compressors. Refer to TECHNICAL DATA [For transmission(s) 0BK] or TECHNICAL DATA [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB]

To ensure compressor lubrication on start-up, at least 40 cm3 of refrigerant oil must be poured into the compressor. The remainder can be added to the new reservoir/receiver/dryer or a refrigerant line. Refer to TECHNICAL DATA [For transmission(s) 0BK] or TECHNICAL DATA [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB]

If on an open refrigerant circuit dirt enters the A/C compressor (for example during an accident) the A/C compressor must be replaced. Refer to A/C COMPRESSOR

Clean the refrigerant circuit (flush with refrigerant R1234yf). Refer to REFRIGERANT CIRCUIT, CLEANING .

-- Replace the dryer cartridge and receiver/dryer.* Refer to REFRIGERANT CIRCUIT [For engine(s) CTUA, CAED, CREH, CEUC, CTGE, CREC, CYNB, CPNB]

-- Assemble, evacuate and recharge the refrigerant circuit. Refer to WORKING WITH A/C SERVICE STATION .