Condensation Water Drain, Removing And Installing: Installing
Installation is done is reverse order, observe the following:
-- Insert the bracket -A- into the condensation water drain hose -B-.
- The bracket must sit evenly in the condensation water drain hose.
-- Insert the bracket and condensation water drain hose into the opening in the body -C- until it audibly engages.
- Position the condensation water drain correctly in the bracket and with pre-tension on the body.
-- If there is pretensioning is not enough, seal the area between the body and the bracket, for example with silicone adhesive. Refer to the Parts information.
Install the condensation water drain hose so that it is not twisted or crushed.
Make sure the carpet does not push up against the condensation water drain hose when installing.
If a condensation water drain hose fits too loose on the A/C unit connection, secure it with a clamp, for example, so that it cannot slide off. Hose clamps. Refer to the Parts information.