LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 782 (Interior Lighting System) >> Diagnosis And Testing >> Interior Lighting >> Pinpoint Tests >> PINPOINT TEST J : The Ambient Lighting Is Inoperative >> PINPOINT TEST J : The Ambient Lighting Is Inoperative

PINPOINT TEST J : The Ambient Lighting Is Inoperative

WARNING: This page is about a different car, the 2016 Ford Expedition. However, it is still accessible from the selected car via links, so may be relevant.

  1. J1 CHECK FOR COMMUNICATION TO THE HVAC MODULE

    • Ignition ON.
    • Using a scan tool, perform network test.

    Does the scan tool communicate with the HVAC module? 

    Yes  GO to  J2.
    No  REFER to Module Communications Network .
  2. J2 CHECK THE CLIMATE CONTROL OPERATION

    • Check the operation of the climate control system and verify that all of the climate controls operate correctly.

    Does the climate control system operate correctly? 

    Yes  GO to  J3.
    No  REFER to Climate Control System General Information .
  3. J3 CHECK THE AMBIENT LIGHTING LED RETURN CIRCUIT FOR AN OPEN

    • Ignition OFF.
    • Disconnect: HVAC Module C228C .
    • Diode check:
      Positive Lead Measurement / Action Negative Lead
      C228C-5
      GFD136910Courtesy of FORD MOTOR COMPANY
      C228C-17

    Does the meter indicate the circuit is good? 

    Yes  GO to  J4.
    No  REPAIR the circuit.
  4. J4 CHECK THE AMBIENT LIGHTING GROUND CIRCUIT FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C228C-8
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground

    Is the resistance less than 3 ohms? 

    Yes  GO to  J5.
    No  REPAIR the circuit.
  5. J5 CHECK FOR CORRECT HVAC MODULE OPERATION

    • Disconnect the HVAC connectors.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • corrosion (install new connector or terminals - clean module pins)
      • pushed-out pins - install new pins as necessary
    • Reconnect the HVAC connectors and make sure they seat and latch correctly.
    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, discontinue this test and follow TSB instructions. If no TSBs address this concern, INSTALL a new HVAC. REFER to Exterior Lighting .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues. CLEAR the DTCs.