LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1162 (RCM Guided Routine Testing -- (4 Of 4)) >> Pinpoint Tests >> Pinpoint Test UA: Second Row Left Buckle Sensor (buckle and inflator separated) >> Normal Operation and Fault Conditions

Normal Operation and Fault Conditions

WARNING: This page is about a different car, the 2018 Lincoln Navigator. However, it is still accessible from the selected car via links, so may be relevant.

The RCM continuously monitors the second row left seatbelt buckle switch circuits for the following faults: 

PPT U RCM DTC FAULT TRIGGER CONDITIONS

DTC Description Fault Trigger Conditions
B140C:11 Second Row Driver Side Seatbelt
Sensor: Circuit Short to Ground
Sets when the RCM senses a short to ground from the second row left seatbelt buckle switch circuit for more than 6 seconds.
B140C:12 Second Row Driver Side Seatbelt
Sensor: Circuit
Short to Battery
Sets when the RCM senses a short to voltage from the second row left seatbelt buckle switch circuit for more than 6 seconds.
B140C:13 Second Row Driver Side Seatbelt
Sensor: Circuit Open
Sets when the RCM senses an open from either second row left seatbelt buckle switch circuit for more than 6 seconds.
B140C:1D Second Row Driver Side Seatbelt
Sensor: Circuit
Current Out of Range
Sets when the RCM measures current outside of an acceptable range from the second row left seatbelt buckle switch circuit for more than 6 seconds.