Pinpoint Test H : A Door Lock Indicator Is Inoperative: Notes
WARNING: This page is about a different car, the 2018 Lincoln Navigator. However, it is still accessible from the selected car via links, so may be relevant.
Refer to Wiring Diagram Remote Keyless Entry and Alarm for schematic and connector information.
Refer to Wiring Diagram Interior Lamps for schematic and connector information.
Normal Operations and Fault Conditions
REFER to: Handles, Locks, Latches and Entry Systems - System Operation and Component Description .
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B12BA:11 | Lock Status LED Front: Circuit Short To Ground | Sets by the DDM and PDM when a short to ground is detected from the door lock indicator voltage supply circuit. |
Possible Causes
- Wiring, terminals or connectors
- Door latch
- PDM
- DDM
- BCM
- Door lock indicator (part of the wiring harness)