Pinpoint Test G : The RH (Right-Hand) Power Fold Seat Is Inoperative: Notes
WARNING: This page is about a different car, the 2018 Lincoln Navigator. However, it is still accessible from the selected car via links, so may be relevant.
Refer to Wiring Diagram Power Seats for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Third Row Seats - System Operation and Component Description .
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1231:1C | Right Seat: Circuit Voltage Out of Range | This DTC sets when the RH seat left third row power fold motor output circuit voltage is out of a specified range. |
| B1231:63 | Right Seat: Circuit/Component Protection Time-Out | This DTC sets when the RH seat left third row power fold motor circuit protection has timed out. |
| B1231:99 | Right Seat: Exceeded Learning Limit | This DTC sets when the RH seat left third row power fold motor exceeded its learning limit. |
| B154C:11 | Right Seat Right Motor Speed/Position Sensor: Circuit Short To Ground | This DTC sets when the RH seat right third row power fold motor speed/position sensor circuit is shorted to ground. |
| B154C:12 | Right Seat Right Motor Speed/Position Sensor: Circuit Short To Battery | This DTC sets when the RH seat right third row power fold motor speed/position sensor circuit is shorted to voltage. |
| B154C:13 | Right Seat Right Motor Speed/Position Sensor: Circuit Open | This DTC sets when the RH seat right third row power fold motor speed/position sensor circuit is open. |
| B154D:11 | Right Seat Right Motor Output: Circuit Short To Ground | This DTC sets when the RH seat right third row power fold motor output circuit is shorted to ground. |
| B154D:12 | Right Seat Right Motor Output: Circuit Short To Battery | This DTC sets when the RH seat right third row power fold motor output circuit is shorted to voltage. |
| B154D:13 | Right Seat Right Motor Output: Circuit Open | This DTC sets when the RH seat right third row power fold motor output circuit is open. |
| B1551:11 | Right Seat Left Motor Output: Circuit Short To Ground | This DTC sets when the RH seat left third row power fold motor output circuit is shorted to ground. |
| B1551:12 | Right Seat Left Motor Output: Circuit Short To Battery | This DTC sets when the RH seat left third row power fold motor output circuit is shorted to voltage. |
| B1551:13 | Right Seat Left Motor Output: Circuit Open | This DTC sets when the RH seat left third row power fold motor output circuit is open. |
| B1552:11 | Right Seat Left Motor Speed/Position Sensor: Circuit Short To Ground | This DTC sets when the RH seat left third row power fold motor speed/position sensor circuit is shorted to ground. |
| B1552:12 | Right Seat Left Motor Speed/Position Sensor: Circuit Short To Battery | This DTC sets when the RH seat left third row power fold motor speed/position sensor circuit is shorted to voltage. |
| B1552:13 | Right Seat Left Motor Speed/Position Sensor: Circuit Open | This DTC sets when the RH seat left third row power fold motor speed/position sensor circuit is open. |
Possible Causes
- Wiring, terminals or connectors
- Third row seat control switch
- Seat assembly
- SCMJ