Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1049 (Climate Control (Service Information - Refrigerant 134A)) >> 87 Air Conditioning >> A/C Service Station, Connecting >> Service Station, Connecting With No Connection On Low- And High Pressure Side Of Refrigerant Circuit >> SERVICE STATION, CONNECTING WITH A/C Adapter Set - Adapter:VAG1785 TO REFRIGERANT CIRCUIT

SERVICE STATION, CONNECTING WITH A/C Adapter Set - Adapter:VAG1785 TO REFRIGERANT CIRCUIT

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.
GWWA87-0004Courtesy of AUDI OF AMERICA, LLC

-- Remove the cap from the connection with valve -A- (at A/C compressor).

-- Attach the O-ring -B- to the connection (8.9 mm; 1.8 mm).

-- Screw the Adapter:VAG1785/10  -C- onto the connection -B-.

-- Install the valve opener -D- with the appropriate seal in the charging hose connection.

NOTE:

The type of valve opener -D- and seals required depends on charging hose used (specific to manufacturer).

The quick-release coupling adapter is not required for connection on the low-pressure side of Audi vehicles.

Screw the charging hose -E- (to the service station) onto the A/C Adapter Set - Adapter 10:VAG1785/10  .

NOTE:

To minimize the amount of air and moisture penetrating into the charging hoses and thus into the refrigerant circuit, the charging hoses should be connected together as illustrated.

GWWA87-0005Courtesy of AUDI OF AMERICA, LLC

A - Charging hose to service station

B - Hand shut-off valve

C - Charging hose (short version) with valve opener for connection to adapter -D-

D - A/C Adapter Set - Adapter 10: VAG1785/10 

E - Charging hose (short version) with quick-release coupling adapter (for vehicles with quick-release coupling adapter on low-pressure side).

-- Perform the planned tests and measurements.