Distance Measurement
-- Switch on the :VAS6350/2 .
The following display appears.
The display shows how to stop the :VAS6350/2 . Press the corresponding button.
- Attach with Front Edge
- Attach with Rear Edge
-- Hold the :VAS6350/2 -2- flush in the bracket on one side of the calibration board (attach with rear edge). The :VAS6350/2 -2- must sit securely on the bracket.
-- Press the measuring button briefly.
The laser switches on.
-- The laser beam from the :VAS6350/2 -2- must hit the lower, enlarged section of the paddle -1-.
If this is not the case, the paddles must be corrected accordingly via clamping screws on the :VAS6350/1 .
-- Use one hand to secure the :VAS6350/2 in the bracket on the Calibration Tool :VAS6350A while the laser beam is visible on the paddle.
-- Then press the measurement button for the distance measurement briefly.
-- Write down the value.
-- Repeat this measurement on the other side of the :VAS6350A in the same way for the rear wheel.
The distance value must be the same on both sides.
If values are not identical:
-- Align the :VAS6350A long enough so that both sides are identical.
Pay attention when aligning the :VAS6350A , that the :VAS6350/3 from the :VAS6350A strikes the center of the Audi rings and the indicator of the level remains centered. Adjust if necessary.