Home >> Audi >> 2010 >> S4 Automatic DCT >> Repair and Diagnosis >> External Pages >> Different car >> Section 1037 (Entertainment System & Communication System (Service Information - 2 Of 2)) >> Communication >> Rearview Camera System >> Rearview Camera System, Calibrating >> Calibration Tool, INSTALLING AND ALIGNING >> Calibration Board Orientation

Calibration Board Orientation

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S6, 2018 Audi A6 Quattro, 2018 Audi A6, 2017 Audi S6, and 2017 Audi A6 Quattro. However, it is still accessible from the selected car via links, so may be relevant.

-- Position the calibration platform behind the vehicle at a distance of 1.47 m to 1.90 m to the rear wheels, see -dimension A- in the overview illustration. Refer to Calibration Tool .

-- Bring the :VAS6350A  into a horizontal position.

-- To do so, twist plastic feet under calibration device so that air bubble in level is located exactly in the center of the indicator -arrow-.

GWWN94-10686Courtesy of AUDI OF AMERICA, LLC
WARNING:

Make sure light does not reflect off the calibration board.

Reflections impair the Rearview Camera -R189- and may make it impossible to perform the calibration.

-- Switch on the :VAS6350/3  -1- on the calibration board and adjust the entire :VAS6350A  so that the laser beam hits the center of vehicle rear above the Audi rings.

GWWA91-10995Courtesy of AUDI OF AMERICA, LLC

-- Make sure the Audi rings are centered on the rear. Correct the laser beam accordingly.