LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2010 >> A4 2.0T >> Repair and Diagnosis >> External Pages >> Different car >> Section 362 (Hybrid Transaxle (Service Information)) >> Motor Cable >> Installation [08/2013 - ] >> Installation [08/2013 - ]

Installation [08/2013 - ]

WARNING: This page is about a different car, the 2014 Lexus ES 300h. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSTALL MOTOR CABLE 
    WARNING:

    Wear insulated gloves.

    NOTE:
    • Do not damage the terminals, connector housings or inverter with converter assembly when connecting them.
    • Do not touch the connector waterproofing rubber or terminals.
    • Do not allow any foreign matter or water to enter the inverter with converter assembly.
    1. Clean and degrease the bolt holes.
    2. Install the motor cable to the hybrid vehicle transaxle assembly with 4 new bolts.

      Torque: 8.5 N*m (87 kgf*cm, 75 in.*lbf) 

    3. Connect the 2 clamps to the No. 3 automatic transmission case cover in the order shown in the illustration.
      Fig 1: Identifying Motor Cable Clamps
      GTY319165Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Install the motor cable to the hybrid vehicle transaxle assembly with the bolt.

      Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

    5. Connect the clamp to the hybrid vehicle transaxle assembly.
    6. Connect the motor cable to the inverter with converter assembly.
    7. Connect the 3 motor cable clamps.
    8. Using an insulated tool, install the motor cable to the inverter with converter assembly with the 3 bolts.

      Torque: 8.0 N*m (82 kgf*cm, 71 in.*lbf) 

      NOTE:
      • The connector should be connected securely.
      • The bolts should be fastened securely.
  2. INSTALL UPPER INVERTER COVER  . Refer to INSTALLATION [08/2013 - ] - Step 22
  3. INSTALL AIR CLEANER CASE SUB-ASSEMBLY  . Refer to INSTALLATION [08/2013 - ] - Step 62
  4. INSTALL AIR CLEANER FILTER ELEMENT 
  5. INSTALL AIR CLEANER CAP SUB-ASSEMBLY  . Refer to INSTALLATION [08/2013 - ] - Step 2
  6. INSTALL INLET AIR CLEANER ASSEMBLY  . Refer to INSTALLATION [08/2013 - ] - Step 65
  7. INSTALL COOL AIR INTAKE DUCT SEAL  . Refer to INSTALLATION [08/2013 - ] - Step 3
  8. INSTALL SERVICE PLUG GRIP 

    Refer to INSTALLATION [08/2013 - ]