Pinpoint Test Y : The GFM (Generic Function Module) (Remote Cd Changer) Does Not Respond To The Diagnostic Scan Tool
WARNING: This page is about a different car, the 2018 Lincoln Navigator. However, it is still accessible from the selected car via links, so may be relevant.
- Y1 CHECK THE GFM (GENERIC FUNCTION MODULE) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: GFM C3028 .
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C3028-1 Ground
Is the voltage greater than 11 volts?
Yes GO to Y2 No VERIFY the BCM fuse 33 (20A) is OK. If OK, REPAIR the circuit. If not OK, Refer to the Wiring Diagram Information to identify the possible causes of the circuit short. - Y2 CHECK THE GFM (GENERIC FUNCTION MODULE) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C3028-10 Ground
Is the resistance less than 3 ohms?
Yes GO to Y3 No REPAIR the circuit. - Y3 CHECK THE HS-CAN3 (HIGH-SPEED CONTROLLER AREA NETWORK 3) CIRCUITS BETWEEN THE GFM (GENERIC FUNCTION MODULE) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN
- Disconnect: GWM C2431
Are the resistances less than 3 ohms?
Yes GO to Y4 No REPAIR the circuit in question. - Y4 CHECK FOR CORRECT GFM (GENERIC FUNCTION MODULE) OPERATION
- Ignition OFF.
- Disconnect and inspect the GFM connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the GFM connector. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, General Service Bulletin (GSB), SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new GFM. REFER to: Compact Disc (CD) Player . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.