LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2009 >> S4 Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1373 (AIR CONDITIONING R1234yf (REFRIGERANT CIRCUIT) (COUPE)) >> 87 Air Conditioning >> Refrigerant Circuit >> General Description - Refrigerant Circuit Components >> Pressure Relief Valve

Pressure Relief Valve

WARNING: This page does not describe the selected car, but rather 23 other vehicles, including the 2017 Audi S5, 2017 Audi A5 Quattro, 2016 Audi S5, 2016 Audi A5 Quattro, and 2015 Audi S5. However, it is still accessible from the selected car via links, so may be relevant.

The Pressure Relief Valve Is Installed On The A/C Compressor Or Receiver/Dryer.

GWWV87-1456Courtesy of AUDI OF AMERICA, LLC

At a pressure of approximately 38 bar (551 psi) positive pressure, the valve opens and closes again once pressure has dissipated (at approximately 35 bar (508 psi)).

Refrigerant Does Not Escape Completely.

NOTE:

Depending on the version, a transparent plastic washer -B- may be installed on the pressure relief valve -A-, which breaks off as soon as the valve is activated.

GWWA87-11386Courtesy of AUDI OF AMERICA, LLC

Depending on the pressure relief valve version -A-, an additional cover -C- can be slid onto the pressure relief valve -A-. If the pressure in the refrigerant circuit does rise above the pressure relief valve -A- opening pressure and the pressure relief valve opens, the refrigerant does not escape in one direction, but rather it is distributed through the openings -D- under the cover -C-.

If it is necessary to replace a pressure relief valve -A- pay attention to the tightening specification when installing (depending on the manufacturer of the A/C compressor and the version). On "Denso", "Sanden" and "Valeo" A/C compressors an O-ring is installed (tightening specification currently 10 Nm on "Denso" and "Zexel- / Valeo" as well as 15 Nm on "Sanden" A/C compressor). On "Delphi" A/C compressor for example a seal is installed (tightening specification is currently 15 Nm).

Replace the seals (seal or O-ring). Refer to the Parts Information.

If the seals (seal or O-ring) that are installed on the pressure relief valve are not available as a replacement part, the removed seals may be used as an exception (check for damage before installing). If the removed seal is damaged or deformed if necessary replace with a commercially available component. Refer to the Parts Information.

After charging the refrigerant circuit check the installed pressure relief valve for leaks for example using an electronic leak detector.