LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2009 >> Q7 4.2 >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 26 (3.0L - Exhaust System & Emission Controls - Engine Code: CATA) >> 26 Exhaust System, Emission Controls >> Reducing Agent Metering System >> Reducing Agent Active Tank, Draining

Reducing Agent Active Tank, Draining

WARNING: This page is about a different variant/trim than selected.

Special tools and workshop equipment required 

Procedure 

Follow all safety precautions. Refer to WORKING ON REDUCING AGENT METERING SYSTEM, VEHICLES WITH SCR CATALYTIC CONVERTER .

Follow the guidelines for clean working conditions. Refer to FUEL SUPPLY, INJECTION SYSTEM AND CHARGING SYSTEM CLEAN WORKING CONDITIONS .

-- On a vehicle with air suspension, activate vehicle lift mode. Refer to VEHICLE LIFT MODE .

-- Remove the right rear wheel housing liner. Refer to Wheel Housing Liners .

NOTE:

Place a clean cloth under the separating location to catch any reducing agent that may leak out.

Seal off all open lines and connections with clean plugs.

Fig 1: Identifying Return Line -1-, Extension Hose -2-
GWWA20-10499Courtesy of AUDI OF AMERICA, LLC
WARNING:

The reducing agent can cause skin irritation.

  • Avoid contact with skin and eyes! Always wear protective gloves and safety glasses.
  • If reducing agent should get on your skin, wash it off immediately with soap and water.
  • If reducing agent gets in your eye, rinse the eye for several minutes with water.
  • Never inhale or swallow the reducing agent!
  • Should you swallow any reducing agent, rinse your mouth, drink plenty of water and contact a doctor immediately.

-- Disconnect the return line -1- on the reducing agent delivery unit by pressing the release button.

-- Attach an extension hose -2- to the reducing agent delivery unit connection -arrow- and drain the reducing agent into the container.

-- Open the fuel tank flap.

Fig 2: Identifying Locking Cap -2-
GWWA20-10560Courtesy of AUDI OF AMERICA, LLC

-- Remove the locking cap -2- from the reducing agent filler tube.

NOTE:

Ignore -item 1-.

-- Drain the reducing agent inside the active tank as far as possible into the drip tray using a hose.

-- Seal any open lines and connections with a clean plug from the Engine Bung Set VAS 6122.

After filling, the following steps must be performed:

-- Adapting Adaptation Value after Draining Reducing Agent or Replacing Components. Refer to ADAPTING ADAPTATION VALUE AFTER DRAINING REDUCING AGENT OR REPLACING COMPONENTS .