Fuel Supply Line To Metering Pump, Bleeding, Vehicles With Parking Heater

WARNING: This page is about a different variant/trim than selected.
NOTE:

After working on the fuel delivery unit, bleed the fuel supply line for the metering pump on vehicles with a parking heater.

Special tools and workshop equipment required 

Procedure

Fig 1: Identifying Metering Pump -1- And Fuel Supply Line -2-
GWWA20-10396Courtesy of AUDI OF AMERICA, LLC

-- Connect the Suction PumpVAS5226 to the compressed air.

-- Remove the fuel supply line -2- from the fuel tank at the metering pump -1-. Disconnect the connector couplings, refer to CONNECTOR COUPLINGS, SEPARATING .

-- Connect the Suction PumpVAS5226 with the adapter from the Hand Vacuum PumpVAS6213 to the fuel supply line and bleed it by extracting briefly.

-- Install the fuel supply line to the metering pump.

-- Switch the parking heater on and let it run approximately 10 minutes at full throttle.