Home >> Audi >> 2009 >> Q7 4.2 >> Repair and Diagnosis >> External Pages >> Different car >> Section 6 (3.0L - Cooling System - Engine Code(S): CJTB, CJTC, CNAA, CJWB, CJWC, CJWE, CTWA, CTWB) >> 19 Cooling System >> COOLANT PIPE AND After-Run Coolant Pump -V51- >> After-Run Coolant Pump -V51-, REMOVING AND INSTALLING >> Removing

After-Run Coolant Pump -V51-, REMOVING AND INSTALLING: Removing

WARNING: This page is about a different car, the 2015 Audi Q7, 2014 Audi Q7, 2013 Audi Q7, 2012 Audi Q7, and 2011 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.
WARNING:

Risk of scalding due to hot steam and hot coolant.

  • The coolant system is under pressure when the engine is warm.
  • Reduce pressure by covering coolant reservoir cap with a cloth and carefully opening.

-- Open the coolant reservoir cap.

-- Remove the front noise insulation -1-. Refer to NOISE INSULATION, REMOVING AND INSTALLING .

Fig 1: Identifying Front/Rear Noise Insulation
GWWA10-10441Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the connector -2-.

-- Remove the bolt -1-.

-- Place the Shop Crane - Drip TrayVAS6208 under engine.

-- Loosen the clamps -arrows- and remove the coolant hoses from the After-Run Coolant Pump -V51-.

Fig 2: Identifying After-Run Coolant Pump (If Equipped)
GWWA19-10599Courtesy of AUDI OF AMERICA, LLC