LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2009 >> A6 Base >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Electrical Equipment >> 27 - Starter, Generator, Cruise control >> Battery >> Battery, rapid-charging

Battery, rapid-charging

CAUTION:
  • Battery must not be connected to vehicle electrical system when performing rapid charging. Disconnect ground and positive cables → Battery, removing and installing .
  • Do NOT attempt to rapid-charge completely discharged batteries.
CAUTION:
  • Battery sealing plugs must always be firmly screwed in during charging, voltage measurement and load measurement.
  • Ensure good ventilation.
  • Smoking or open flames are not allowed in rooms in which batteries are being charged. The reason for this is that inflammable gasses are formed during battery charging process.
  • Observe safety regulations of charger and battery manufacturers.
NOTE:
  • Battery temperature must be at least 10 ° C.
  • Rapid charging of batteries should only be performed in exceptional circumstances (e.g. boost starting) as rapid charging may cause damage.